Table 4-2.  Troubleshooting - Continued MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION 2.  Vent Assembly leaks (cont'd) - Check coupling for breaks or cracks. - Check for loose or missing hexagon head bolts. - Remove and replace coupling (Ref . para. 4-9). - Tighten or replace bolts. 3.  Pressure Relief Valve remains open - Check relief valve for debris in tube or on pivot pin. - Clean relief valve (Ref. para. 4-9). 4.  Hose Assembly Coupling leaks - Check female coupling gaskets for damage or wear. - Check couplings on hose for dirt, damage, or wear. - Remove and replace gaskets - Remove dirt or any foreign objects inside couplings. If leak continues, replace hose assembly. 5.  Filler Assembly leaks - Check for loose or missing hexagon head bolts. - Tighten or replace bolts as necessary 4-5