TM 5-4930-237-10
a. If installed, disconnect adapters (20, 23, 26, or 30) as follows:
(1) DELETED
(2) Disconnect adapter (20, 23, 26, or 30) from 2 inch discharge hose (11).
(3) Install dust cap (21, 24, 27, or 31) on adapter (20, 23, 26, or 30).
(4) Install dust cap (12).
b. DELETED
c. Operate HEMTT tanker to evacuate fuel. Refer to TM9-2320-279-10-1 for details.
d. Disconnect 2 inch discharge hose (11) and elbow connector (14) as follows:
(1) Close FLOW handles (13).
(2) Pull interlock pin (16).
(3) Disconnect 2 inch discharge hose (11) from elbow connector (14).
(4) Install dust cap (12) on 2 inch discharge hose (11).
(5) Install dust cap (15) on elbow connector (14).
(6) Pull interlock pin (16) and disconnect elbow connector (14) from 2 inch discharge host (11).
(7) Install dust cap (15) on elbow connector (14).
(8) Repeat steps (1) through (7) for other 2 inch discharge hose (11) and elbow connector (14).
e. Disconnect 2 inch discharge hoses (11) and tee connectors (8) as follows:
(1) Close FLOW handles (10 and 1.3).
(2) Disconnect 2 inch discharge hose (11) from tee connector (8).
(3) Install dust cap (12) on 2 inch discharge hose (11).
(4) Install dustcap (9) on tee connector (8).
(5) Repeat steps (1) through (4) for other 2 inch discharge hoses (11) and tee connectors.
2-18
Change 5
|