TM 5-4930-237-10
Table 2-1. Preventive Maintenance Checks and Services (PMCS) Continued
NOTE: Within designated interval, these checks are to be performed in the sequential order listed.
B - Before
D - During
A - After
W - Weekly
M - Monthly
Item
No.
8
9
10
11
12
13
B
Interval
D
A
W
M
Item to be
Inspected
Swivel Adapter
CCR Nozzle
Overwing Nozzle
Recirculation
Nozzle
D1 Nozzle
Grounding Rod
Procedures
Check For and Have
Repaired or Adjusted
Check for damaged body, and
signs of leaks or cracks.
Check body for seals/boot
damage or loss.
Check dust caps for damage or
loss.
Check interlock pin for damage
or loss.
Refer to TM 5-4930-235-13&P.
Check for damaged body, and
signs of leaks or cracks.
Check dust caps for dama~e or
loss.
Check for damaged body, and
signs of leaks or cracks,
Check body for seals/boot
damage or loss.
Check dust caps for damage or
loss.
Check ground plug for
loose/frayed cable and damage
to plug or cable.
Check plug and hose for damage
or loss.
Check for damaged body, and
signs of leaks or cracks.
Check body for seals/boot
damage or loss.
Check dust caps for damage or
loss.
Check strainer for damaged or
dirty screen.
Examine grounding rod for
cracks in the striker and
hanger assembly.
For Readiness Reporting,
Equipment is Not
Ready/Available if:
Outward signs of damage or
leakage.
Seals/boot damaged or missing.
Dust cap damaged or missing.
Interlock pin damaged or
missing.
Outward signs of damage or
leakage.
Dust cap damage or missing.
Outward signs of damage or
leakage.
Seals/boot damaged or missing.
Dust cap damaged or missing,
Outward signs of damage or
missing parts.
Damaged or missing parts
Outward signs of damage or
leakage.
Seals/boot damaged or missing.
Dust cap damaged or missing.
Cracks in striker or hanger
assembly.
Change 1