Complete nozzle assembly. Includes protective caps and grounding connectors.
d.
Will dispense aviation grade jet fuel to aircraft.
e.
Outlet will connect to standard aircraft receptacle without use of an adapter.
f.
Inlet coupling half connects to standard cam-lock type couplings.
g.
Nozzle will not dispense fuel unless connected to aircraft receptacle.
h.
Nozzle contains a vacuum break valve to permit easy removal from receptacle.
i.
Model 125-10000 will connect to other cam-lock couplings.
j.
Model 125-0505 will connect to other unisex couplings.
1-10. Location and Description of Major Components. Refer to Chapter 2, Section I, Description and Use of
Operator's Controls and Indicators.
1-11. Differences Between Models.
a.
Model 125-10000 is equipped with a cam-lock coupler and a dust plug on the inlet end.
b.
Model 125-0505 is equipped with a unisex coupling and a dust plug on the inlet end.
c.
Wherever it is required throughout this manual, model 125-0505 will be identified. All references to model
125-10000 will remain the same.
1-12. Equipment Data. (See Table 1-1.)
Table 1-1. Equipment Data
Weight:
Nozzle Subassembly Only ........................................................................................................... 6.5 pounds (2.95 kg)
Nozzle with Coupling and Outlet Cap ........................................................................................... 7.0 pounds (4.08 kg)
Dimensions:
Length with handle in flow position ...................................................................................... 13-1/4 inches (336.6 mm)
Length with handle in no flow position ................................................................................. 13-5/8 inches (346.1 mm)
Height with handle in flow position ........................................................................................ 6-1/2 inches (165.1 mm)
Height with handle in no flow position .................................................................................... 7-1/8 inches (181-0 mm)
Width .......................................................................................................................................... 4 inches (101.6 mm)
Operating Temperature Range ...................................................................................... -30 degrees F to + 180 degrees F
(-34.4 Degrees C to 82.2 Degrees C)
Inlet Operating Pressure ........................................................................................................... 0 to 125 psi (0 to 862 kPa)
Outlet Operating Pressure ...................................................................................................... 13 to 18 psi (90 to 124 kPa)
Section III. PRINCIPLES OF OPERATION
Refer to Chapter 2, Section I, Description and Use of Operator's Controls and Indicators.