TM 5-4930-234-13&P
3.
Remove cable (4) from ground clip (3).
c.
Inspection.
1.
Inspect ground clip (3) for corrosion, cracks, distortion and spring tension.
2.
Inspect cable (4) for corrosion, cuts, or fraying.
3.
Inspect cable eye (5) for corrosion or distortion.
d.
Replacement. Replace any damaged parts.
e.
Reassembly.
NOTE
Plastic coating must be stripped from end of cable to ensure metal to metal contact at assembly.
1.
Strip about 3/4 inch of plastic cover off each end of cable (4).
2.
Insert one end of cable (4) in cable eye (5). Crimp end of cable eye (5) to cable (4).
3.
Insert other end of cable (4) in ground clip (3). Tighten two set-screws on ground clip (3).
f.
Installation. Insert screw (2) through hole in cable eye (5). Thread screw (2) into nozzle (1) and tighten.
4-10.
CAN-LOCK COUPLING ASSEMBLY (See Figure 4-5).
a.
Removal.
NOTE
Do not drop or lose gasket inside coupling.
1.
Turn coupling (2) counterclockwise to remove from nozzle (1).
2.
Remove o-ring (3) from coupling (2). Replace o-ring (3) if cut or distorted.
b.
Installation.
1.
Install o-ring (3) on threaded end of coupling (2).
2.
Install coupling (2) in nozzle (1) and turn clockwise until hand tight.
4-10
|