TM 5-4930-234-13&P
3.
Make a one inch loop with the cable (6) and slide sleeve (5) over end of cable (6).
4.
Crimp sleeve (5) in place on cable (6).
5.
Repeat steps 1 through 4 for other end of cable (6).
f.
Installation.
1.
Install dust plug (4) in inlet end of nozzle (1).
2.
Install end of cable (6) on ring (3).
4-8.
GROUND PLUG ASSEMBLY (See Figure 4-3).
a.
Removal. Remove screw (2) from nozzle (1).
b.
Disassembly.
NOTE
If cable requires replacement, do not remove cable eye from cable.
1.
Cut cable eye (5) off end of cable (4)
2.
Loosen hex-head nut on ground plug (3).
3.
Remove cable (4) from ground plug (3).
c. Inspection.
1.
Inspect ground plug (3) for corrosion, cracks, or distortion.
2.
Inspect cable (4) for corrosion, cuts, or fraying.
3.
Inspect cable eye (5) for corrosion, or distortion.
d.
Replacement. Replace any damaged parts.
e.
Reassembly.
NOTE
Plastic coating must be stripped from end of cable to ensure metal to metal contact at both ends.
1.
Strip about 3/4 inch of plastic cover off each end of cable (4).
4-7
|