1-9.
NOMENCLATURE CROSS REFERENCE LIST.
Closed Circuit Refueling Nozzle - CCR nozzle, nozzle assembly, nozzle.
Adapter Assembly - Unisex coupling, coupling.
Cam-lock coupling - coupling.
Handle - Flow Handle.
1-10.
DIFFERENCES BETWEEN MODELS.
Model AE83206R: Equipped with cam-lock coupling and dust plug on inlet end.
Model AE83501R: Equipped with a unisex coupling and dust plug on inlet end.
1-11.
SAFETY, CARE, AND HANDLING.
SAFETY:
*
Grounding connectors must be attached before connecting nozzle to aircraft receptacle. Failure to comply
can result in injury or death to personnel.
*
No smoking or open flames are permitted in refueling areas. Failure to comply can result in injury or death to
personnel.
*
Do not use a nozzle that is damaged and/or leaking fuel.
CARE AND HANDLING:
*
Keep handle in NO FLOW (off) position when not in use.
*
Keep dust cap and plug installed when not in use. Dirt or dust can damage internal seals.
*
Do not leave laying on ground. Dirt or dust can interfere with handle and/or pullback sleeve operation.
*
Hand carry to and from aircraft. Do not drag on the ground.
*
Keep exterior clean. Remove dirt, dust, mud or moisture.
Section III. PRINCIPLES OF OPERATION
See Chapter 2, Section I, Description and Use of Operators Controls and Indicators.