TM 5-4930-226-12&P
Figure 3-3. Modified strainer assembly - exploded view.
The following parts are not interchangeable from
ing back on actuating ring cable loop on nozzle as-
one strainer assembly to the other: End, O-ring,
sembly.
Gaskets and Body. However, the complete strainer
b. Inspection. Inspect nipple dust cap, adapter
assemblies are interchangeable. See Appendix E for
dust cap, adapter and housing subassembly for dam-
the correct parts for the strainer assembly that is on
age and cleanliness.
your nozzle.
c. Replacement. To replace the gravity fill
Gravity Fill Adapter Assembly
adapter, simply push the nipple end of the assembly
into the nozzle assembly until an audible click is
a. Remoual. Release adapter (fig. 3-4) by pull-
heard.
3-9
|