3-4 TM  5-4930-226-12&P Table   3-2.   Troubleshooting Malfunction Test or Inspection Corrective Action 1.  LEAKAGE  FROM  COUPLING  DURING  REFUELING Place   latch   handle   in   no-flow   (down)   position.   Reach   inside   of   body   and   remove   the   seal.   Inspect   wiper   seal   for   damage, Replace seal by making sure the “V” slot is facing towards handle, place seal onto sleeve. 2. HANDLE  FAILS  TO  OPERATE  SMOOTHLY Inspect   handle   area   for   signs   of   dirt   or   other   foreign   matter. Clean area around handle. 3.  NOZZLE  FAILS  TO  MAKE  CONNECTION Step   1.   Insure   that   the   actuating   ring   is   in   the   latched   (forward)   position. Retract actuating ring by pulling cable loop. Step  2.   Inspect   coupling   end   of   nozzle   for   signs   of   dirt   or   other   foreign   matter. Clean area around coupling end. Step  3.   Check   for   presence   of   dirt   or   other   foreign   matter   around   actuating   ring   and   housing. Clean area around actuating ring and housing. 4. INADEQUATE  FUEL  FLOW Step   2.   Check   strainer   for   presence   of   dirt   or   other   foreign   matter. To do this, remove strainer assembly (figs. 3-2 and 3-3) from nozzle assembly. Open cam-lock keeper and remove dust plug. Unscrew body from end; remove gasket (fig. 3-2) or O-ring (fig. 3-3) and remove strain- er. Clean strainer by removing all foreign matter or dirt. Step   2.   While   the   strainer   is   removed,   inspect   it   for   any   damage. Replace strainer by replacing gasket (fig. 3-2) or O-ring (fig. 3-3) on strainer. Place body and coupling over strainer and screw into end. Hand tighten only. Replace dust plug on coupling. 5. LEAKAGE  FROM  STRAINER  BODY  OR  AT  CAM-LOCK  COUPLER Remove   strainer   assembly   (fig.   3-2)   from   nozzle   assembly.   Open   cam-lock   keeper   and   remove   dust   plug   (8).   Unscrew   body   (5)   from end   (l),   remove   gasket   (4),   strainer   (3)   and   gasket   (2)   from   end   (l).   Remove   gasket   (7)   from   coupling   (6),   Unscrew   coupling   (6) from   body   (5)   if   damaged   or   leaking.   Inspect   gaskets   for   damage. Replace any damaged gaskets. Place gasket (7) in coupling (6). Replace end (1) in nozzle assembly. Re- place gasket (2) in end (1). Replace gasket (4) on strainer (3). Place body (5) and coupling (6) over strainer (3) and screw into end (1). Hand tighten only. Replace dust plug (8) on coupling (6). 6. LEAKAGE FROM STRAINER BODY OR AT CAM-LOCK COUPLER (Serial No. Range 0001 thru 0470) Remove   strainer   assembly   (fig.   3-3)   from   nozzle   assembly.   Open   cam-lock   keeper   and   remove   dust   plug   (7).   Unscrew   body (4)   from   end   (l);   remove   strainer   (3)   and   O-ring   (2)   from   end   (1).   Remove   gasket   (6)   from   coupling   (5).   Unscrew   coupling (5)   from   body   (4)   if   damaged   or   leaking.   Inspect   O-ring   for   damage. Replace damaged O-ring. Place gasket (6) in coupling (5). Replace end (1) in nozzle assembly. Replace O. ring (2) in end (1). Place body (4) and coupling (5) over strainer (3) and screw into end (1). Hand tighten only. Replace dust plug (7) on coupling (5).

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business