TM 5-4320-308-13
2-1. ASSEMBLY AND PREPARATION FOR USE (Continued)
a.
The pumping assembly is shipped in its storage container which is fitted with four carrying handles. Use handles
to lift the pumping assembly from the carrier. The gross weight of the pumping assembly is 455 pounds (206 kg) so that
it can easily be lifted by four men.
b.
The storage container (1) houses the pump assembly, hoses, nozzles, ground rod, drum unloader, and Y-
connectors.
(1)
Unlatch the two lock bolts (2) that secure the covers (3). Raise the covers.
(2)
Grasp the pump assembly (4) by the rubber grip handles (5) and lift the pump assembly and ground rod
assembly (6) from the storage container (1). The ground rod assembly is attached to the pump.
(3)
Remove three suction hose assemblies (7), three discharge hose assemblies (8), and drum unloader (9)
from around hose positioner (10) in the storage container (1).
(4)
Remove two nozzle assemblies (11) from nozzle assembly mounting brackets (12) on storage container
cover (3) by loosening fasteners on nozzle assembly bracket clamps and lifting nozzle assemblies from
brackets.
(5)
Remove Y-connectors (13) from base assembly of pump assembly (4).
c.
The pump assembly (4) comes fully assembled, ready for use after attaching suction (intake) and discharge
hoses. Locate pumping assembly on firm, moderately level area as close as conveniently possible to source of fuel
supply. Choose an area which will provide enough room around pumping assembly to allow convenient servicing.
WARNING
The pumping assembly must be connected to a suitable ground before operation. Arcing caused by buildup of static
electricity may ignite volatile fluids and cause explosion and fire.
(1)
Drive ground rod (6) into earth. Make sure grounding cable makes metal-to-metal contact with pump and
rod.
(2)
Remove dust caps from suction (intake) female coupling (14) and suction hose assembly (7) adapter.
Connect male end of suction hose assembly to suction (intake) female coupling. Highest point in suction
hose assembly should be at the pump.
(3)
Remove dust caps from suction hose assembly (7) coupler and drum unloader 90 degree elbow (15).
Connect suction hose assembly coupler to drum unloader 90 degree elbow.
(4)
Remove dust caps from discharge male coupling (16) and discharge hose assembly (8) coupler. Connect
female end of discharge hose assembly to discharge male coupling.
2-4
|