TM 5-4320-308-13
4-9. REPAIR Y-CONNECTORS
This task covers:
a.
Cleaning/Inspection
b.
Repair
INITIAL SETUP
Materials/Parts
Equipment
Condition
Diesel fuel oil (Item 2, Appendix E)
Para
Condition Description
2-1
Y-Connectors removed from
pumping assembly.
General Safety Instructions
Well-ventilated area required.
CLEANING/INSPECTION:
WARNING
Death or serious injury could occur if fuel is not handled carefully. Use in a well-ventilated area
away from open flame, arcing equipment, ignition sources, heaters, or excessive heat. Always
store fuel in proper, marked containers. DO NOT SMOKE.
Death or serious injury could occur if compressed air is directed against the skin. Do not use
compressed air for cleaning or drying unless the pressure is/has been reduced to 30 psi (2.06 bar)
or less. When working with compressed air always use chip guards, eye protection, and other
personal protective equipment.
1
Clean male-double female Y-connector
(1) and female-double male Y-connector (2)
with clean diesel fuel and dry
with
compressed air.
2
Inspect for cracks, score marks, burrs,
signs of deterioration, and obvious damage.
REPAIR:
If parts are not repairable, replace.
4-16
|