TM 5-4320-308-13
3-33. SHORT TERM STORAGE (30 days or less) (Continued)
b.
Remove suction hose from female coupling (3) (intake).
c.
Remove discharge hose from male coupling (4) (discharge).
d.
Remove pipe plug (1) and drain pump case (2). Replace pipe plug (1).
e.
Clean intake and discharge port threads using a wet cloth.
f.
Cover intake and discharge couplings.
g.
Seal all engine openings with moistureproof, vaporproof tape, strong enough to resist puncture and damage from
the expansion of entrapped air.
3-34. INTERMEDIATE TERM STORAGE (more than 30 days)
a.
Connect pump assembly to a water supply. Prime pump, and allow to operate for 10 to 12 minutes or until
normal operating temperature is reached. Shut down engine.
b.
Drain crankcase oil. Then fill crankcase to proper level using MIL-L-21260 preservative lubricating oil, Grade 2,
or equivalent.