TM 5-4320-306-24
2-13. TEST/REPLACE/REPAIR BATTERY CABLE ASSEMBLIES, BATTERIES, AND CHARGING RECEPTACLE
(Continued)
ASSEMBLY/TEST
1.
Assemble screws (28), nuts (2, 6, and 10), and terminal lugs (3, 7, and 11 ) onto positive battery cables (8),
negative battery cables (4), and jumper battery cable (12).
2.
Test positive battery cable assembly and negative battery cable assembly for electrical continuity between terminal
lugs (3 and 7) and opposite end of cables
3.
Test jumper battery cable assembly for electrical continuity between the two terminal lugs (11 )
4.
Inspect cables that do not have continuity for good electrical connection between cable ends and terminal lugs If
connections are good, inspect cable according to INSPECTION/ TEST/REPAIR steps 6, 7, and 8
INSTALLATION
1.
Reconnect positive battery cable (8) to starter relay (27).
2-38
|