TM 5-4320-306-24
Table 2-1. Organizational Preventive Maintenance Checks and Services - Continued
W - Weekly
Q - Quarterly
M - Monthly
S - Semiannually
Item
Interval
Item To Be
No.
W
M
Q
H
Inspected
Procedures
7
Turbocharger -
Continued
CAUTION
Do not remove carbon or dirt buildup
from the compressor or turbine impel-
lers. The turbocharger must be disas-
sembled to thoroughly clean the
impellers. Even small deposits remaining
on the blades unbalance the impeller
and damage the turbocharger.
·
Check for carbon or dirt buildup on impellers
(4) and casing port. If buildup is present, the
turbocharger must be cleaned Notify direct
support
·
Check for oil on the impeller (4) The
presence of oil indicates seal leaks. Oil seal
leaks are caused by blocked air intake ducts
or damaged oil seals If the air filter and in-
take ducts are not blocked, the turbocharger
oil seals must be replaced Notify direct
support
2-19
|