TM 5-4320-306-24
2-8. INSPECTING AND SERVICING BATTERIES (Continued)
CAUTION
Be sure that during installation the batteries are installed and connected in parallel. If batteries are
not connected in parallel, damage to starter and controls may occur.
NOTE
Refer to battery circuit plate mounted on inside top of battery box when connecting battery cable
assemblies.
k.
Connect positive battery cable assembly (7) to
positive (+) terminal lug (4). Tighten screw (8) and nut
(9) securely.
l.
Connect negative battery cable assembly (10) to
negative (-) terminal lug (5). Tighten screw (11) and nut
(12) securely.
m.
Connect cable jumper (13) to positive and
negative terminals (4 and 5) as shown.
n.
Lightly coat battery posts (14 and 15) and
terminals (4 and 5) with MIL-G-10924 grease.
o.
After placing batteries (2) into battery box (1),
close battery box top (3). Be sure catches (16) are
securely fastened over strikes (17).
2-8
|