TM 5-4320-306-24
2-34. TEST/REPLACE STARTER MOTOR (Continued)
SYSTEM TEST
WARNING
Touching exhaust system during test can cause severe burns
CARBON MONOXIDE (EXHAUST GAS) CAN KILL YOU
Exposure to exhaust gases produces symptoms of headache, dizziness,
loss of muscular control, drowsiness, or coma. Brain damage or death can
result from severe exposure.
Fumes from engines become concentrated with poor ventilation. Operate
engine in a ventilated area only.
While running engine, be alert for fumes If someone is overcome, expose
to fresh air; keep warm and still; give artificial respiration if needed. Seek
medical attention. Administer oxygen, if available.
GOOD VENTILATION IS THE BEST DEFENSE AGAINST EXHAUST
POISONING.
1
Move START/STOP switch on control panel to START, press in and hold OIL BY-PASS switch, and move
STARTER switch to UP position until engine starts. Engine should start within 10 seconds
NOTE
Starter transmission must be correctly aligned with flywheel ring gear.
2
If engine does not start, check starter, electrical system, and batteries If engine still will not start, refer to
troubleshooting guide.
3
If systems are working properly and engine still will not start and does not crank, notify direct support
maintenance, and replace starter
2-120
|