TM 5-4320-305-24
4-4. REPAIR INJECTION PUMP (Continued)
30 Check camshaft projection as follows: a. Place
measuring bar over shaft of camshaft drive end. Keep
firm pressure on measuring bar.
b. Measure and record distance from housing face to
measuring bar using vernier caliper as shown.
c. If distance measured is between 0.36 to 0.39 inch
(9.1 to 9.9 mm), skip steps d through m and
proceed with step 31.
d. If distance measured is not between 0.36 to 0.39
inch (9.1 to 9.9 mm), remove two screws (43),
timing indicator (44), two spacers (45), two screws
(41), and two lockwashers (42).
e. Tap governor end of camshaft using rubber mallet. Remove bearing cap and camshaft as an assembly.
f. Install protective sleeve KDEP 2874 onto bearing cap (81). Press bearing cap from camshaft using '
mechanical puller. Remove protective sleeve KDEP 2874.
g. Remove and discard oil seal (83). Remove bearing cone (89) from governor end of camshaft using
mechanical puller.
4-26
|