TM 5-4320-305-10
Table 2-2. Preventive Maintenance Checks and Services - Continued
B - Before Operation
D - During Operation
A - After Operation
W - Weekly
INTERVAL
ITEM TO BE INSPECTED
ITEM
PROCEDURE
Equipment is Not
NO
B
D
A
W
Ready/Available If:
33
Engine Shutdown Valve (Electrical).
Check for loose or missing electrical connector (1). Check
for frayed insulation or other damage to wires (2) running
to electrical connector.
34
Ether Start Kit
During cold
weather opera-
Check that ether cylinder (1) is firmly in place. The cylinder tion the valve
should be finger tight in valve (2).
does not release
Inspect the cylinder and valve for dents, corrosion, or other ether.
damage.
Verify valve operation
by pulling knob (3)
for 3 seconds or less
If the valve operates
freely but no ether is
released, replace the
cylinder, and test the
valve again.
Inspect hose (4) for
leaks or cracks. The
hose should be se-
cured to fitting (5)
at both ends.
2-49
|