4-14. REPLACE PUMP CASE ASSEMBLY (Continued)
CLEANING:
Dry cleaning solvent P-D-680 (safety or Stoddards Solvent)
is potentially dangerous. Avoid repeated and prolonged
breathing of vapors and skin contact with the liquid. Do
not use near open flame, arcing equipment, or other igni-
tion sources. Always wear eye protection and protective
clothing. The flash point of P-D-680 is 100° to 138°F (38°
to 59°C).
Death or serious injury could occur if compressed air is
directed against the skin. Do not use compressed air for
cleaning or drying unless the pressure is/has been reduced to
30 psi (2.06 bar) or less. When working with compressed
air always use chip guards, eye protection, and other per-
sonal protective equipment.
Clean with solvent and dry with compressed air.
INSPECTION:
1
Inspect pump case assembly (2) for rust, corrosion, cracks, or other damage. Replace pump case
assembly if damaged.
2
Inspect threaded holes for damage to threaded inserts (3, 4, and 5). If threads are damaged,
notify direct support maintenance.
INSTALLATION:
Install screws (1) with insert in pump case assembly (2). Tighten evenly in an alternating pattern.
Torque to 32 to 35 foot-pounds (4.43 to 4.84 mkg).
4-19
|