TM 5-4320-304-14
TM 08922A-14/1
2-4. OPERATING PROCEDURE
d. Stopping.
2-28
(Continued)
Immediate shutdown of the engine without a 5-minute idle
time may cause damage to engine. Do so only when made
necessary by overriding system requirements or emergency
conditions.
(1) Slowly move throttle control hand lever toward LOW position to idle speed. Allow engine
to idle for 5 minutes to allow engine operating temperature to stabilize.
NOTE
If centrifugal pump unit is to be reused in its present place-
ment and alignment, be prepared to close suction and dis-
charge valves on hoses attached to the pump. This will retain
liquid in pump volute and reduce or eliminate priming re-
quirements.
(2) Move throttle control hand lever to extreme right (LOW) position.
(3) Close any suction and discharge valves that are installed in hoses.
|