TM 5-4320-304-14
TM 08922A-14/1
Section III. OPERATION UNDER USUAL CONDITIONS
2-3. ASSEMBLY AND PREPARATION FOR USE
a. The centrifugal pump unit comes fully assembled, ready for use after attaching suction (intake)
and discharge hoses (not supplied with unit).
(1) Connect suction hose to hose adapter (1) on suction (intake) flange (2). Highest point in
the suction hose should be at the pump.
(2) Connect discharge hose to hose adapter (3) in discharge port (4).
(3) Make sure that connections are tight.
b. Perform category B (before operation) PMCS contained in Table 2-2 or verify that category B
PMCS was performed. Report any problems to organizational maintenance.
c. The following paragraphs contain instructions for starting, operating, and stopping the unit.
2-24
|