5-8. TEST/REPLACE/ADJUST INJECTION PUMP (Continued)
Adjustment of Delivery Lift:
NOTE
Delivery lift controls the quantity of
at full throttle (full load).
1
With flywheel timing marks (2) (11.5 to 12.5 degrees)
aligned with reference mark (3), rotate dial gage
612 087 00 face to zero.
fuel which is injected
2
Slowly rotate flywheel (1) in a clockwise direction
when facing fIywheel until dial gage indicates
0.052 inch (1.34 mm).
3 Stop flywheel at position indicated in step 2.
Death or serious injury could occur if
fuel is not handled carefully. Use in a
well-ventilated area away from open
flame, arcing equipment, ignition sources,
heaters, or excessive heat. Always store
fuel in proper, marked containers, DO
NOT SMOKE.
4
At this point, fuel should emerge again from
spill pipe (1) of spill device (2).
NOTE
If fuel does not emerge, turn the extra
fuel device. If results are not obtained,
turn the extra fuel device in the oppo-
site direction.
5-19
|