TM 5-4320-304-14
TM 08922A-14/1
5-4. REPAIR PUMP CASE (Continued)
2
Chase threaded hole using appropriate size tap.
Dry cleaning solvent P-D-680 (safety or Stoddards Solvent)
is potentially dangerous.
Avoid repeated and prolonged
breathing of vapors and skin contact with the liquid. Do
not use near open flame, arcing equipment, or other ignition
sources. Always wear eye protection and protective
clothing. The flash point of P-D-680 is 100° to 138°F (38°
to 59°C).
Death or serious injury could occur if compressed air is
directed against the skin.
Do not use compressed air for
cleaning or drying unless the pressure is/has been reduced
to 30 psi (2.06 bar) or less. When working with compressed
air always use chip guards, eye protection, and other
personal protective equipment.
3
Using dry cleaning solvent and a stiff-bristled brush, clean threaded hole thoroughly.
4
Using clean compressed air at 30 psi (2.06 bar) maximum discharge pressure, blow out
threaded hole to make sure that all solvent has been removed and no particles are left in the
hole.
5
Coat new insert (1, 2, or 3) with zinc chromate primer coating.
6
Insert each insert to a depth of 1 to 1.5 pitches below the top surface of the tapped hole in
pump case (4). Wipe off excess primer.
7
Remove drive tang from installed insert.
5-5
|