TM 5-4320-243-15
ME 4320-243-15/3-22
Figure 3-23. Magneto adjustment.
1. Determine that battery is fully charged and that
all battery and starting motor cables are
serviceable and properly installed.
2. Remove solenoid-to-staring motor connector
and connect voltmeter as shown in A above. If
voltage is indicated, solenoid relay is defective
and must be replaced.
3. Install the solenoid-t00-starting motor connector.
4. Connect voltmeter as shown in B above. If
battery voltage (24 volts) is not indicated, the
starting motor is defective.
5. Momentarily connect a jumper as shown in C
above. The voltmeter reading should drop to
zero and starting motor should start engine. If
voltmeter reading does not drop to zero,
replaced. If voltmeter reading drops to zero but
starting motor fails to start engine, starting
motor
is
defective.
3-30
|