TM 5-4320-234-34
Table 2-1. Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
CENTRIFUGAL PUMP CONTINUED
b.
Remove nuts and lockwashers that secure pump body to the bearing housing; slide the pump body straight out to disengage it from the
remainder of the pump which is secured to the engine.
c.
Disassemble the pump following the sequence of index numbers in figure 2-17.