APPENDIX A TM 07661B-14/1 (a) Dry Chemical Shut-Off Valve - Closed (b) Purge Valve - Closed (c) Charge Valve - Open (d) Nitrogen Cylinder -Closed (2) AFFF System. (a) AFFF Shut-OFF Valve - Closed (b) Purge Valve - Closed (c) Charge Valve - Open (d) Nitrogen Cylinder - Closed b. Operation.    The  fire  extinguisher  as  emergency  equipment  is  always  maintained  in  an  operational  ready status.  When the unit is needed for fighting a fire, proceed as follows: NOTE If  remote  hose  reel  is  needed  in  reaching  the  fire,  connect  the  remote  unit  to  the  base  unit  per paragraph c before opening the nitrogen cylinder valves. (1) Open both nitrogen cylinder valves.  The AFFF tank will pressurize in 1-2 seconds, the dry chemical tank should pressurize within 10 seconds. (2) Rotate  the  AFFF  control  rod  and  the  dry  chemical  control  rod  to  full  open  position.    The  system discharge lines will pressurize up to the twin nozzle assembly. (3) Remove nozzle assembly from nozzle bracket and withdraw all the hose from the reel. (4) Approach fire from upwind and attack fire with open dry chemical nozzle, sweeping side to side. (5) When headway is gained on fire, open AFFF nozzle. (6) Work fire slowly downwind with both nozzles open. NOTE Full  flow  AFFF  can  be  maintained  for  approximately  two  minutes.    The  dry  chemical  agent  will dispense within approximately 75 seconds at full flow. (7) When fire is extinguished, close both nozzles. (8) When area clears, verify that no smoldering pockets remain to reignite the fuel. c. Operation  with  Remote  Hose  Reel.    When  the  remote  hose  reel  is  needed  to  extend  the  reach  of  the  fire extinguisher, proceed as follows. CAUTION Shut off nitrogen supply and depressurize systems before connecting remote hose reel. (1) Extend handline assembly from fire extinguisher hose reel to its maximum length (150 feet). (2) Pull the remote hose reel cart to the end of the handline. (3) Remove twin nozzle assembly from handline hoses by releasing the quick-disconnects on the nozzle. (4) Separate the cart input hoses (5, figure 2-7) by releasing A 2-14

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business