4-11  600 Gpm Hoseline Pump Operation -Cont'd . CAUTION PRESSURE GAGES Check the pressure gages on the pumps routinely to assure that they are accurate.  These are the  only  operating  pressure  gages  in  the  TPT  system.    Misoperation  causing  equipment failure and personnel injury could be the result of a lack of accurate pressure indication. 4-12  350 Gpm Transfer Pump Information on the 350 GPM transfer pump is found in para. 2-4.4 and Fig. 2-16.  Fig. 2-17 is the performance curve for the pump.  Detailed instructions are in the Department of the Army technical manual TM-5-4320-226-14 supplied with the pump.  The pump must be operated in accordance with the U.S.  Army manual and study of it is recommended. WARNING TRANSFER PUMP OPERATION Observe all Warnings and Cautions contained in TM 5-4320-226-14. WARNING DRY SUCTION Do not leave pump operating and unattended at anytime, if possible, but particularly not when a fabric collapsible tank is nearing its empty point.  Continued operation with a dry suction can result in pump failure. WARNING OVERPRESSURE Do not operate the pump at discharge pressures in excess of 150 psig.  Equipment including the pump is not designed for pressures above 150 psig. CAUTION BACK FLOW It is noted that this pump does not have a built-in check valve and thus back flow is possible. Judicious   operation   of   the   discharge   gate   valve   is   required   to   prevent   back   flow   if   the hydraulic conditions are such that back flow can occur. 4-13  Filter Separator Operation Information   on   the   filter   separators   is   found   in   para.   2-4.7   and   Fig.   2-20.      Detailed   operating   instructions   are   in Department  of  the  Army  technical  manual  TM  5-4330-211-12  supplied  with  the  equipment.    Operation  must  be  in accordance with that manual and study of it is recommended.  Note that the filter separators are rated at 350 gpm and that if loading rates at the dispensing set are in excess of this, it will be necessary to operate two (2) filter 4-25

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business