TM 10-8110-203-12&P 4-10.  REPLACE QUICK-DISCONNECT ADAPTER - continued. Figure 4-3.  Quick-Disconnect Adapter Replacement. b.   Installation. WARNING Do  not  use  excessive  pressure  when  cleaning  pipe  nipple  threads.    Sharp  threads  can  cause serious injury. 1.   Clean the threads of the pipe nipple (3). WARNING Do not use excessive pressure when or applying sealant onto pipe nipple threads.  Sharp threads can-cause serious injury. 2.  Apply a coating of thread sealant on the pipe nipple(3) threads. 3.  Install the quick-disconnect adapter (2) on the pipe nipple (3). 4.  Place the protective cap (1) on the quick disconnect adapter (2). 4-6