TM 10-8110-203-12&P
4-10. REPLACE QUICK-DISCONNECT ADAPTER - continued.
Figure 4-3. Quick-Disconnect Adapter Replacement.
b. Installation.
WARNING
Do not use excessive pressure when cleaning pipe nipple threads. Sharp threads can cause
serious injury.
1. Clean the threads of the pipe nipple (3).
WARNING
Do not use excessive pressure when or applying sealant onto pipe nipple threads. Sharp threads
can-cause serious injury.
2. Apply a coating of thread sealant on the pipe nipple(3) threads.
3. Install the quick-disconnect adapter (2) on the pipe nipple (3).
4. Place the protective cap (1) on the quick disconnect adapter (2).
4-6
|