TM 10-6630-247-13&P
2-12. PREPARATION FOR MOVEMENT - cont.
c.
Disassemble Flash Point Tester.
Remove Slow Speed Stirrer. Refer to figure 2-16.
(1)
Disconnect electrical cord (8) from power cable (9).
(2)
Remove belt (7) from pulleys (4 and 5).
(3)
Loosen clamp (1) and remove slow speed stirrer (2) and clamp from support rod (3).
(4)
Remove clamp (1) from mounting hole in bottom of slow speed stirrer (2).
Figure 2-16. Slow Speed Stirrer Removal.
2 - 33
|