TM 10-6630-247-13&P
2-7. ASSEMBLY AND PREPARATION FOR USE - cont.
Connect Heater and Condenser. Refer to figure 2-11.
NOTE
Various sizes of corks are over packed with the test kit. Use the size cork
that best fits your application.
(16) Select a cork (1) from the test kit that will fit snugly into inlet tube (2) of condenser (3).
(17) Using cork boring tool (4), cut hole through center of cork (l). Slide cork onto end of vapor
tube (5).
NOTE
Heat shield must be positioned right-side-up with door at front of heater,
as shown.
(18)
(19)
(20)
(21)
(22)
(23)
(24)
(25)
Lower heat shield (6) over flask (7) and heater (8). Position heat shield so that door (9)
will provide access to heater control knob (10).
Move condenser (3) as needed to mate inlet tube (2) with vapor tube (5) on flask (7). Make
sure cork (1) is properly seated and no gap is visible between mated components.
Slide adapter (11) onto outlet tube (12). Small end of cone goes on first.
Place cylinder cover (13) on end of outlet tube (12).
Position graduated cylinder (14) under outlet tube (12).
Pull down adapter (11) until cover (13) is pressed against top of graduated cylinder (14).
Select a cork ( 15) from the test kit that will fit snugly into top of flask (7).
Using cork boring tool (4), cut hole through center of cork ( 15) to fit thermometer (16)
snugly,
NOTE
Temperature range of the thermometer and positioning of thermometer
bulb in the flask will be determined by the ASTM for the type of fuel
being tested.
(26) Push thermometer (16) into cork (15).
(27) Insert cork (15) and thermometer (16) into top of flask (7).
(28) Connect electrical cord (17) to power cable (18).
e.
Setup Fuel Sampling Equipment. Refer to ASTM D1085.
2-24
|