TM 10-5430-242-12&P
0005 00
Change 1
0005 00-16
PACKING AND FOLDING INSTRUCTIONS FOR GTA AND RELIANCE MODEL TANKS
1. Empty the tank completely:
a. Lay the tank flat.
b. Lift up one of the corners of the tank with a drain decal and flip over to expose drain fitting. There
are two drain decals.
c. Disconnect drain hose and install drain plug.
d. Lay corner back so that tank is flat. Pick up the other corner of tank with a drain decal to uncover
second drain fitting. Repeat step 1c.
2. Remove vent fitting assembly:
a. Locate vent fitting assembly in center top of tank.
b. Remove upper portion of vent assembly by releasing quick-disconnect.
c. Wrap upper portion with cushioning material and secure with tape.
d. Secure dust cap on vent fitting assembly.
e. Apply cushioning material to vent fitting, and secure with pressure sensitive tape (Item 3, WP
0042 00).
3. Remove air from inside tank and remove filler/discharge assembly elbows:
a. Locate filler/discharge assemblies located on top of tank.
b. Remove upper portion (4-inch 90° elbow) of each filler/discharge assembly by releasing quick-
disconnect.
c. Wrap upper portion with cushioning material, secure with pressure sensitive tape (Item 3, WP
0042 00). Set aside.
d. Secure dust cap on one of the filler/discharge assemblies.
e. Wrap permanently attached cushioning material around filler/discharge fitting and secure in place
with pressure sensitive tape (Item 3, WP 0042 00).
f.
Repeat steps 3b through 3e for other filler/discharge assembly.
|