TM 10-5430-242-12&P
0021 00
Change 1
0021 00-2
SERVICE
WARNING
Dry cleaning solvent, A-A-59601, used to clean parts, is potentially dangerous to
personnel and property. It produces toxic and flammable fumes. Use only in well
ventilated areas. Avoid repeated and prolonged skin contact. Do not use solvent
near an open flame or near excessive heat. The flash point of the solvent is 100F
to 130F (38C to 59C).
CAUTION
Dry cleaning solvent, A-A-59601, used to clean parts, must not come into contact
with any part of the fuel tank fabric. Damage to the fabric will occur.
1. Clean all parts with dry cleaning solvent and dry thoroughly with rags.
2. Inspect all mechanical parts for cracks, dents, breaks, and wear. Replace the component if
unserviceable.
ASSEMBLY
1. Coat threads of female coupling (9) with thread sealing compound or anti-seize tape, and install
female coupling (9) in ball valve (7).
2. Connect chain (12) and two key rings (13) to dust plug (10) and female coupling (9).
3. Install new gasket (11) on dust plug (10).
4. Push cam-lever arms (8) on female coupling (9) outward, away from body of female coupling (9).
5. Install dust plug (10) in female coupling (9).
6. Push cam-lever arms (8) on female coupling (9) inward toward body of female coupling (9) until
locked.
7. Coat threads of male coupling (3) with thread sealing compound or anti-seize tape, and install male
coupling (3) in ball valve (7).
8. Connect chain (5) and two key rings (6) to male coupling (3) and dust cap (2).
9. Push cam-lever arms (1) on dust cap (2) outward, away from body of dust cap (2).
10. Install dust cap (2) on male coupling (3).
11. Push cam-lever arms (1) on dust cap (2) inward toward body of dust cap (2) until locked.
INSTALLATION
Install the drain ball valve on the drain hose assembly.
END OF WORK PACKAGE
|