TM 10-5430-239-12&P
0008 00
TROUBLESHOOTING PROCEDURE
WARNING
FLAMMABLE FUEL. Do not allow smoking within 100 feet (30.50 meters)
of the storage area. Post NO SMOKING signs around the area. Avoid
getting fuel on the body or clothing. If clothing becomes saturated with
fuel, remove the clothing immediately and wash body with hot soapy water
and soak clothing in soapy water. Avoid spillage of fuel. When spillage
occurs, cover the affected area with dry soil to reduce its rate of vaporization.
Be certain a suitable fire extinguisher is present and that it is properly
charged and positioned so as to be readily available in case of fire. Death or
serious injury may result if personnel fail to strictly observe safety precautions.
FILLER/DISCHARGE GATE VALVE ASSEMBLY
SYMPTOM
Gate valve assembly leaks.
MALFUNCTION
Check for loose or missing hexagon head bolts and nuts.
CORRECTIVE ACTION
Tighten or replace nuts and bolts (WP 0027 00).
Check for loose valve stem packing nut.
CORRECTIVE ACTION
Tighten packing nut (WP 0027 00).
0008 00-8
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |