TM 10-5430-239-12&P
0007 00
TROUBLESHOOTING PROCEDURE
WARNING
FLAMMABLE FUEL. Do not allow smoking within 100 feet (30.50 meters)
of the storage area. Post NO SMOKING signs around the area. Avoid
getting fuel on the body or clothing. If clothing becomes saturated with
fuel, remove the clothing immediately and wash body with hot soapy water
and soak clothing in soapy water. Avoid spillage of fuel. When spillage
occurs, cover the affected area with dry soil to reduce its rate of vaporization.
Be certain a suitable fire extinguisher is present and that it is properly
charged and positioned so as to be readily available in case of fire. Death or
serious injury may result if personnel fail to strictly observe safety precautions.
FILLER/DISCHARGE ASSEMBLY
SYMPTOM
Filler/discharge assembly leaks.
MALFUNCTION
Check female coupling half gaskets for damage or wear.
CORRECTIVE ACTION
Replace gaskets (WP 0013 00).
Check coupling halves on hoses for dirt, damage, or wear.
CORRECTIVE ACTION
Remove any dirt or foreign objects inside coupling halves.
If leak continues, notify unit maintenance for repair.
Check for loose or missing hexagon head bolts.
CORRECTIVE ACTION
Notify unit maintenance for repair.
Check preformed packing between closure plate and tank fitting for nicks,
breaks, or distortion.
CORRECTIVE ACTION
Notify unit maintenance for repair.
Check gasket on both sides of closure plate for damage or breaks.
CORRECTIVE ACTION
Notify unit maintenance for repair.
0007 00-5
|