TM 10-5430-238-12&P
0028 00
SERVICE
WARNING
Dry cleaning solvent, A-A-59601, used to clean parts, is potentially dangerous
to personnel and property. It produces toxic and flammable fumes. Use only in
well ventilated areas. Avoid repeated and prolonged skin contact. Do not use
solvent near an open flame or near excessive heat. The flash point of the
solvent is 100F to 130F (38 C to 59 C).
1. Clean all parts with dry cleaning solvent and dry thoroughly with rags.
2. Clean packing grooves thoroughly with detergent and hot water.
3. Inspect all mechanical parts for cracks, dents, breaks, and wear. Replace the component if
unserviceable.
2
9
1
3
5
6
8
4
7
ASSEMBLY
1. Lubricate new o-ring (9) with silicone compound. Position o-ring (9) into the packing groove located
on the tank fitting.
2. Position drain cover plate (3) on the tank fitting, and align the fastening holes.
3. Install drain cover plate (3) to the tank fitting with screws (7) and washers (8), hand tightening
screws (7) and washers (8).
4. Attach the S-hook of chain assembly (4) under one screw (7) head. Torque all screws (7) to 30 in-lbs
(3.41 Nm).
5. Apply sealing compound or anti-seize tape to drain plug screw (5) threads.
6. Attach chain assembly (4) to drain plug (6), drain plug screw (5), and drain cover plate (3).
7. Screw drain hose (2) clockwise until firmly engaged in drain cover plate (3).
8. Screw gate valve (1) clockwise until firmly engaged with drain hose (2).
END OF WORK PACKAGE
0028 00-2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |