Check the quick-disconnect coupling for dirt, damage, or wear.
CORRECTIVE ACTION
Remove the dirt or debris from inside the quick-disconnect
coupling. Replace the hose assembly if the corrective action
fails to stop the leakage. Notify Unit Maintenance.
TROUBLESHOOTING PROCEDURE
DRAIN HOSE ASSEMBLY
SYMPTOM
Drain hose assembly leaks.
MALFUNCTION
Check for leaks or breaks in the drain hose.
CORRECTIVE ACTION
If hose is damaged, notify Unit Maintenance.
TROUBLESHOOTING PROCEDURE
FILLER/DISCHARGE GATE VALVE ASSEMBLY (Models WTM3KF, MIL-T-52983B, M52983-50,
PD52983-50, BA92-162, FCE574-81-1-A, SC5430-97CLE01)
SYMPTOM
Female coupling or male flange adapter leaks.
MALFUNCTION
Check the female coupling for missing or loose hex-head cap screws, hex nuts,
washers, and lockwashers. Check for damaged or missing coupling gasket.
CORRECTIVE ACTION
If hardware is loose or missing, notify Unit Maintenance.
If female coupling gasket is damaged or missing, replace gasket.
See WP 0011 00.
Check the flange gasket for damage or leaks.
CORRECTIVE ACTION
If damaged or leaking, notify Unit Maintenance.
Check the male flange adapter for missing or loose hex-head cap screws, hex
nuts, washers, and lockwashers.
CORRECTIVE ACTION
If damaged or loose hardware, notify Unit Maintenance.