TM 10-5430-237-12&P
0023 00
0023 00-1
UNIT MAINTENANCE
BALL VALVE, MALE AND FEMALE CAM-LOCK COUPLINGS
(Models 3-K-W-O-A/Z/GTA-Z60TPW)
REMOVAL, SERVICE, REPAIR AND INSTALLATION
INITIAL SETUP
Tools
Tool Kit, General Mechanics Equipment Condition
(Item 3, Table 2, WP 0026 00)
Tank drained (WP 0005 00)
Materials/Parts
Cleaning Compound
(Item 1, WP 0030 00)
Rag, Wiping
(Item 2, WP 0030 00)
Chain
(Figure 1, WP 0031 00)
REMOVE
Dust Cap
1. Pull cam-lever arms (1) on dust cap (2) out, away from body of cap (2).
2. Remove dust cap (2) from coupling (3).
3. Disconnect chain (4) and key ring (5) from dust cap (2).
Coupling
Unthread coupling (3) from ball valve (6).
|