TM 10-5430-237-12&P
0007 00
0007 00-6
CORRECTIVE ACTION
Perform emergency repairs (WP 0006 00).
TROUBLESHOOTING PROCEDURE
FILL/DISCHARGE FITTINGS
SYMPTOM
Fill/discharge fittings leak.
MALFUNCTION
Check fill/discharge fittings (7 and 8) for loose, damaged, or missing bolts.
CORRECTIVE ACTION
Tighten as necessary or notify Unit maintenance for repair.
Make sure dust plug/cap are securely installed on fill/discharge fittings (7 and 8)
and that cam-lever arms are secured.
CORRECTIVE ACTION
Properly install dust plug/cap, if required.
NOTE
Water should be drained from tank before attempting to inspect or replace
a gasket.
Check gasket, installed in both fill/discharge fittings (7 and 8) for damage (WP
0021 00 and WP 0022 00 respectively).
CORRECTIVE ACTION
Replace gasket (Item 1, WP 0033 00).
END WORK PACKAGE
|