TM 10-5430-237-12&P 0006 00
0006 00-4
NOTE
It may be necessary to increase the size of the tears in order to be able to insert
the bottom plate of the clamp.
4. Loop cord around wrist (1) to prevent loss of clamp into tank.
5. Slip the bottom plate of the clamp (2) through the hole or tear and rotate it until it is centered and its
length runs with the tear.
6. Pull bottom plate up against fabric, and slide top plate and wing nut (3) down cord and onto threaded
stud (4) of bottom plate.
CAUTION
Do not over tighten, as stud threads may be stripped, or damage to tank fabric may occur.
7. With plates aligned, tighten wing nut (5) to clamp the tank wall between the two plates. Tighten
enough to stop leak.
INTERIM NUCLEAR, BIOLOGICAL, AND CHEMICAL (NBC) DECONTAMINATION PROCEDURES.
NOTE
Detailed decontamination procedures can be found in: FM 3-3, FM 3-4,
and FM 3-5.
General.
The following emergency procedures can be performed until field NBC decontamination facilities are
available.
|