TM 10-5430-236-12&P 0017 00 0017 00-4 TROUBLESHOOTING PROCEDURE DRAIN FITTING ASSEMBLY SYMPTOM Drain fitting assembly leaks. MALFUNCTION Check for loose or missing screws and washers on drain fitting assembly. CORRECTIVE ACTION Replace missing screws and washers (WP 0022 00). Torque loose screws to 96 inch-pounds (10.84Nm) (WP 0022 00). Inspect preformed packing for cuts and distortion. CORRECTIVE ACTION Replace preformed packing, if damaged (WP 0022 00). Inspect tank compression fitting for cuts, punctures, elongated holes and tears. CORRECTIVE ACTION If compression fitting or tank fabric is damaged, replace tank.   END OF WORK PACKAGE