TM 10-5430-236-12&P
0022 00
0022 00-2
ASSEMBLY
1. Connect chain (7) to coupling half (8) and cap (9) with two key holders (6).
2. Install new gasket (10) in cap (9).
INSTALLATION
1. Lubricate new preformed packing (4) with silicone compound. Position preformed packing (4) and
drain fitting (3) on compression fitting (5). Install drain fitting (3) in same location as noted in removal.
2. Install eight screws (1), and flat washers (2). Torque screws (1) to 96 in-lbs (10.84Nm). Refer to WP
0036 00 for torquing sequence.
WARNING
Do not use excessive pressure when applying sealing compound onto threads.
Sharp thread edges can cause serious injury.
3. Coat threads of coupling half (8) with sealing compound and install coupling half (8) in drain fitting (3).
END OF WORK PACKAGE
1
|