TM 10-5430-1232-12&P
STEP 2-SIDE A
ENLARGED VIEW-DOUBLE FOLDED
Figure 4-17. Second Fold
f. Screw dust plug into drain assembly.
g. Remove vent assembly (do not install dust cap).
h. Fold side A (see figure 4-16.) toward the center of the tank bringing that side flush with the vent
opening.
(1) Make certain that the vent opening is unobstructed. Continue to remove air from the tank by
evacuating by walking back and forth across the tank after it is folded.
(2) Fold from side A (see figure 4-17.) again toward the center of the tank bringing the folded edge from
Step h flush with the vent opening. Make certain that the vent opening remains unobstructed.
(3) Continue to remove product and air from the tank by evacuating with a pump and walking back and
forth across the tank after it is folded.
4-30
|