TM 10-5430-232-12&P
4-12 Filler/Discharge Assembly.
This task covers: Repair
INITIAL SETUP
Tools
Tool Kit, General Mechanic's, Appendix B, Section III, item 2
Torque wrench (ft-lb), Appendix B, Section III, item 2
Materials/Parts
Cleaning solvent, item 1, Appendix F
Cleaning Compound, item 4, Appendix F
Rags, item 6, Appendix F
Silicone compound, item 7, Appendix F
Preformed patching, Appendix D, Section II, item 16
CAUTION
Be sure to take off the closure plate before removing the flanged adapter.
The flanged adapter Is bolted to the closure plate and suction stub. If It Is
removed first, the suction stub will fall Into the tank.
NOTE
The filler/discharge fitting on the discharge end requires a female/male
elbow. The filler/discharge fitting on the fill end requires a female/female
elbow.
DISASSEMBLY (see figure 4-9)
1 Remove 6-inch elbow (1) by pulling outward on cam-lever arms (2). Lift elbow
from flanged adapter (3).
2 Remove elbow gasket (4) from inside of elbow (1).
3 Remove 20 screws (5) and washers (6) and lift closure plate (7) from collapsible
tank fitting (8).
4 Lift preformed packing (9) from inside packing groove in tank fitting (8).
5 Remove screws (10), and washers (11) from remaining assembly. This releases
suction stub (12) from bottom of closure plate (7) and flanged adapter (3) and
flange gasket (13) from top and bottom of closure plate (7).
6 Remove gasket (14) from inside of dust cap (15).
Change 1