TM 10-4930-250-13&P
(2) START-RUN-STOPswitchin STOPposition.
(3) INTAKE HEATER switch in OFF position.
(4) FAULT LIGHTS switch in ON position.
(5) EMERGENCY STOP switch released.
(6) Close control box cover.
ac. Remove multi-conductor
control cable W201 from the storage cabinet in the accessory module, route through
cutout on upper lip of stowage cabinet and connect to 1A1J2 on engine module. Connect adjacent dust caps
together.
ad. Remove battery power cable W202, NATO connector end, from storage cabinet in the accessory module, route
through cut out on upper lip of cabinet and connect to 1A1J1 on engine module. Connect adjacent dust cap
together.
ae. Position ENGINE SWITCH to RUN position and observe PUMPAGE HOT flashes once, ALTNTR
and LOW
OIL PRESSURE illuminate and remain lit, and ENGINE HOT indicator does not illuminate. If the listed
conditions do not occur, determine cause before operating AAFARS.
af.
Place FAULT LIGHTS switch in BLACKOUT position.
ag. Restore ENGINE Switch to STOP position.
ab. Fill engine fuel tank or connect external fuel source.
ai.
Install optional acoustic cover on purnp-engine module, if provided with system, by placing acoustic cover over
engine end of pump-engine module and fastening to module frame with attached straps.
2-14
|