TM 10-4930-250-13&P
b. Installation.
Rubberglovesshouldbewornwhenhandlingfuelingsystemcomponentsdueto thetoxiceffectsof
some fuel additives.
(1)
Clean the threads on the outlet reducer (15) and pump assembly (10) inlet coupling as required.
(2) Place the pump end of the pump assembly (10) in a vise.
(3)
Wrap three or four complete layers of teflon tape on the threads of the pump inlet coupling (17). Apply a bead of
thread sealant over the teflon tape and install and tighten the pump inlet coupling (17) on the pump assembly (10).
(4)
Wrap three or four complete layers of teflon tape on the threads of the outlet reducer (15). Apply a bead of thread
sealant over the teflon tape and install and tighten the reducer/outlet coupling assembly on the pump assembly (10).
(5)
Remove the pump assembly (10) from the vise and remove four bolts (11), lock washers (12) and flat washers (13)
from pump assembly (10), position pump assembly in the frame (6) and loosely install the four bolts (11), lock
washers (12) and flat washers (13) that hold the pump end to the frame (6).
(6)
Install and tighten the two bolts (7), lock washers (9) and flat washers (9) that hold the motor end to the frame (6).
(7) Tighten the four pump end bolts (11).
(8)
Use the four screws (1), nuts (2) and washers (3) to attach the power cable connector (4) to the module frame (6).
Install the dust cap lanyard (5) to the upper left mounting screw (1).
4-29
|