TM    10-4930-248-13&P 5-2. CCR    NOZZLE ASSEMBLY REPAIR - continuted: C. Assembly - continued. (15) Place    housing (17),   with    discharge end   facing     up,  into    a  soft  face   vise   and    tighten only enough to  prevent housing from   turning or  falling from    vise. (16) Aline    body   wrench with    nine    locking     lugs   and   press    down   until    the    collar    (28)   trips    in  the forward position. CAUTION To   reduce     the   friction between the   locking lugs   and   the   collar, slightly pull back    on   the   collar. NOTE Always aline    the    slot   in  the   collar    and   the    tab   on  the   housing. (17) Tighten the   assembly to  300   in-lb. (18) Pull    back   on   collar    (28)   to  release the   body   wrench, remove body   wrench. Remove nozzle assembly from    vise. BODY   WRENCH .A@ 28 17 ALINE  NOTCH ANDTAB 5-12