TM 10-4930-248-13&P
5-2.
CCR NOZZLE
ASSEMBLY
REPAIR
- continued.
b.
Repair.
WARNING
Drycleaning
solvent, P-D-680 Type III, used to clean parts is potentially
dangerous
to personnel and property.
Use in a well-ventilated
area as the
fumes are dangerous
if inhaled.
Avoid repeated and prolonged
skin contact.
Do not use near open flame or excessive heat. Flash point of solvent is 138*F.
(1)
Clean all components
removed using a wiping rag moistened
with drycleaning
solvent.
Dry with a clean, dry wiping rag.
(2)
Inspect all parts for damage.
Look for damaged threads,
broken, worn, scored, or
deformed
parts, cracks or corrosion.
(3)
Replace damaged
or defective
components.
C.
Assembly.
(1)
Place lug assembly
tool in vise.
(2)
Lubricate
two wiper seals (36) with silicone compound and install into nozzle body (27) in
the internal
groove closest to the threaded
end. Make sure the seals are fully seated
toward the slotted end and the open end of the U shape is facing out toward the threaded
end of body (27).
CAUTION
Lug wire must be positioned
so split is not over one of the slots in body.
(3)
Install lug wire (35) into the lower groove on body (27) and insert body onto the lug
assembly
tool.
NOTE
Stayback
detents
aline with grooves in body and the three slots in the lug
assembly
tool. The detents are placed behind lug wire.
(4)
Install three stayback detents (34) on body (27).
(5)
Insert nine locking lugs (33) onto lug wire (35). Aline locking lugs (33) with remaining
grooves in body (2 7).
5-8
|