TM 10-4930-248-13&P
4-10.
CCR NOZZLE ASSEMBLY
REPAIR
- continued.
WARNING
Drycleaning
solvent, P-D-680 Type III, used to clean parts is potentially
dangerous
to personnel and property.
Use in a well-ventilated
area as the
fumes are dangerous
if inhaled.
Avoid repeated and prolonged skin contact.
Do not use near open flame or excessive heat. Flash point of solvent is 138*F.
b.
Repair.
(1)
Clean parts with drycleaning
solvent. Dry with clean wiping rag.
(2)
Inspect all parts for damage.
Look for damaged
threads,
wom, scored, or deformed parts,
cracks or corrosion.
(3)
Replace damaged
or defective
components.
C.
Assembly.
(1)
Install gasket (14) in dust cover (11).
(2)
Install gasket (12) in coupling half (13).
(3)
Install dust cover (11) on coupling half (13).
(4)
Coat threads
of coupling half (13) with sealing compound.
Wipe off excess compound with
clean, dry wiping rag.
(4)
Clamp strainer
body (6) in a soft face vise and screw coupling half (13) into strainer
body
(6). Remove from vise.
(5)
Position strainer (8) in strainer housing (7).
(6)
Coat preformed packing (9) with silicone compound.
Install packing over strainer
and
press into groove at end of strainer
housing (7).
(7)
Screw strainer body (6) onto strainer housing (7) until hand tight.
NOTE
The two grounding
cable lugs should be closest to the housing.
(8)
Install ground cable assembly (3) and cap assembly (2) on the housing (5) with screw (2).
(9)
Push cap (2) onto collar (1).
4-10
|