TM 10-4930-248-13&P
2-7.
PMCS TABLE.
Table
2-1 contains
a tabulated
listing
of preventive
maintenance
checks
and services
which
must be
performed
by the operator.
Table
2-1. Operator
Preventive
Maintenance
Checks
and Services
(Model 64017B).
NOTE:
Within
designated
interval,
these
checks
are to be performed
in the order listed.
LOCATION
ITEM
INTERVAL
ITEM TO BE
PROCEDURE
NOT FULLY MISSION
NO.
INSPECTED
CAPABLE IF:
CLOSED-CIRCUIT
REFUELING
NOZZLE
I
Before
Locking
Lugs and
Remove
dust
cover.
Inspect
for missing
Lugs
missing
or
Stayback
Lugs
or damaged
lugs.
There
should
be three
damaged.
stayback
lugs and nine locking
lugs.
2
Before
Nozzle Housing
Inspect
for leaks.
Any leak found.
3
Before
Handle
Inspect
handle
action
to see that it
Fails
to operate
operates
smoothly.
smoothly.
4
Before
Cable
Assembly
Inspect
cable for loose connection,
frayed
Damaged
or frayed
or damaged
cables, bent
or damaged
plug
cables.
Bent or
or clip.
damaged
plug or clip.
5
Before
Cap Assembly
Inspect
cap assembly
cap for cracks,
burrs
or damage.
Inspect
cable for
breaks,
frays
and security.
6
Before
Coupling
Inspect
coupling
for leaks.
Any leak found.
Assembly
2-6
|