TM 10-4930-247-13&P
2-10. ASSEMBLY AND PREPARATION FOR USE - cont.
NOTE
Steps 16 through 19 have been deleted.
h.
Fuel Nozzle Installation. Refer to figure 2-11. Variations in fuel system layout are permitted to meet your specific
mission requirements. All of the same type fuel nozzle or a combination of different type nozzles may be used in
the fuel system. The following paragraphs provide instructions for connecting one of each type nozzle.
NOTE
Refer to para 2-10f for connection of non-valved dry break couplings.
D1 Nozzle Installation
(1)
Twist dust cap (1) to the left and remove from coupling (2) on D1 nozzle (3).
(2)
Connect coupling (2) on D1 nozzle (3) to fuel hose (4).
CCR Nozzle Installation
(3)
Remove dust cap (5) from coupling (6) on CCR nozzle (7).
(4)
Connect coupling (6) to fuel hose (8).
(5)
Repeat steps 3 and 4 for remaining CCR nozzles (10 and 17).
Open Port Nozzle Installation
(6)
Pull back collar (9) on CCR nozzle (10) and remove cover (11).
(7)
Remove cover (12) from coupling (13) on open port nozzle (14).
Change 4 2-29
|